Smart IP43 Charger Manufacturer IP43 — 7.1.2. Error states

Smart IP43 Charger 7. Monitoring 7.1. LED indications 7.1.1. Operation states The LEDs on the Smart IP43 Charger unit can be referenced to determine the current charge state and other operational information. Refer to the LED indications in the table below: *1 The RECONDITION LED will also blink during recondition stage. 7.1.2. Error states If an error occurs, the red ALARM LED will illuminate and the charge state LEDs can be referenced to determine the specific error state. Refer to the LED indications in the table below: * Note that warning #31 (Input voltage measurement out of range) uses the same LED blinking code. The difference is that on warning #31 the device continues to work.

Page 49 Monitoring Charge state LOW BULK ABS FLOAT STORAGE ALARM Bulk N/A Illuminated Off Off Off Off Absorption N/A Off Illuminated Off Off Off Recondition *1 N/A Blinking Blinking Off Off Off Float N/A Off Off Illuminated Off Off Storage N/A Off Off Off Illuminated Off Low current mode Illuminated N/A N/A N/A N/A N/A Charging disabled Off Blinking Off Off Off Off Error state LOW BULK ABS FLOAT STORAGE ALARM Bulk time protection Off Blinking Off Off Off Illuminated Internal Error* Off Blinking Blinking Blinking Off Illuminated Charger over-voltage Off Off Blinking Off Blinking Illuminated Charger over-current Off Blinking Off Off Blinking Illuminated Low mains voltage Blinking Off Off Off Off Illuminated BMS connection lost Off Off Off Blink Blink Illuminated