Wiring * CX: Standard Type Receiver * RX: Communication Type Receiver 24VDC ± 10% Transmitter (TX) (CX | RX) Receiver [1] VCC (Brown) [2] GND (Blue) [3] SYNC+ (Orange) [4] SYNC- (Orange / White) [5] FB- (Pink / White) [6] FB+ (Pink) [7] CX:+RS485 (Red) , RX:NPN (Black) Mask Mask [8] CX:

- RS485 (Yellow), RX:PNP (White) Host [9] CX:Output (NPN/PNP/Push-pull) (White) Troubleshooting 25 Indicator Cause Inspection method Light is off Poor power contact • Check the power connection and whether or not the connector pin is bent Irregular flashing of red/ green light Poor beam alignment • Whether it be switched to green light with near-distance alignment • Check whether or not module installation with mounting frame is flat and level • Check whether mounting method is susceptible to vibration Electrical interference • Check whether shielded wire is connected to clean ground • Has external high power machine shutdown been improved?

Light source interference • Is there any external glare affecting device?

• Installation of multiple light curtains should use transmitter/ receiver staggered format Blue/green/red lights are lit simultaneously Over-current • Check load at output end • Check output mode setting Only blue light is lit, and green light is not lit; red light is lit when shielded Power saving setting • Turn off power saving setting Orange light Wiring error, or input voltage exceeds specifications • Check if wire connection is normal • Check if input voltage is within range Abnormal internal signal/ voltage • Contact DELTA service center Red/green lights are lit, and blue lit is not lit Abnormal number of beams • Beam number setting error, or abnormal number of internal beams Contact DELTA service center