Chapter 7: sDIO Module Factory-Supplied Equipment Customer-Supplied Equipment sDIO Wiring Terminal Block Group 1 Power Pins (see text) Customer DC Power Supply Output Group 1 X1 Connector – 44-Pin Female D-Sub (equivalent circuit) Customer AC Power Supply Group 2 Power Pins (see text) Output Group 2 Customer DC Power Supply (equivalent circuit) X2 Connector – 44-Pin Female D-Sub Output Group 3 Signals 0049 – 0056 Digital Output Cable (optional) Output Group 4 Signals 0057 – 0064 Figure 7-11. Typical sDIO Output Wiring Optional DIO Cables The cables that connect to the input and output connectors on the sDIO module can be ordered as a set of four cables:
two input cables and two output cables. These cables have a mating plug on one end and unterminated flying leads on the other end. The wire size of the cables is 0.18 mm 2 (24 AWG). You can use these cables to connect to the digital inputs/outputs in your system or to a wiring block. The cable set is P/N: 90330-01080. To comply with IEC 1131, if you choose to supply a wiring block, it should be capable of accepting wire in the range of 0.18 mm 2 (24 AWG) to 2.0 mm 2 (14 AWG). SmartController EX User’s Guide, 11069-000 Rev. F Page 73 of 92 26 38 39 40 41 42 43 44 28 29 30 15 14 13 12 11 10 9 17 18 19 31 32 33 34 35 36 21 22 7 6 5