omron — Installing 24 VDC Connector

Chapter 3: Installation NOTE : The power requirements for the user-supplied power supply will vary depending on the configuration of the SmartVision MX industrial PC and con- nected devices. A minimum configuration requires 3.0 A at 24 VDC. However, a 24 V, 6 A power supply is recommended to allow for additional current draw from connected external devices and digital I/O loads. Installing 24 VDC Connector In order to maintain compliance with EN standards, DC power must be delivered over a shiel- ded cable, with the shield connected to the frame ground at both ends of the cable. Conductors should be 1.5 mm 2 - 1.85 mm 2 (16 to 14 AWG). The maximum length for the 24 VDC cable is 10 meters.

Use the supplied connector to connect the user-supplied 24 VDC power supply to the SmartVi- sion MX. 1. Locate the 24 VDC connector that is shipped with the SmartVision MX industrial PC. See the following figure. 2. Strip 7 mm of insulation from the end of the wire that connects to the positive output of the 24 VDC supply. 3. Insert the stripped end of the wire into the opening on the right side of the connector. 4. Using a small, flat-blade screwdriver (2.5 mm), tighten the screw clamp on the con- nector. 5. Visually inspect the connection to ensure that the clamp has closed on the wire, not on the insulation. 6.

Gently pull on the wire to confirm that it is securely attached to the connector. 7. Repeat this process to connect the wire from the negative side of the power supply to the center of the connector. 8. Repeat this process to connect the braided shield to the left side of the connector. 9. Plug the connector into the SmartVision MX industrial PC. SmartVision MX User’s Guide, 14362-000 Rev. B Page 15 of 30