Datasheet Narda FieldMan Narda FieldMan ® All-in-one electromagnetic field meter ranging from 0 Hz to 90 GHz The Narda FieldMan performs highly accurate measure- ments of non-ionizing high-frequency radiation and low- frequency fields. Equipped with digital probes for measuring electric or magnetic field strengths, it covers the range from static and low-frequency fields in medical and industrial applications to mobile radio frequencies and millimeter waves. Flat frequency response probes (“flat probes”), as well as so-called shaped probes that evaluate the field strength on the basis of a human safety standard are available.

Probes with built-in FFT analysis enable spectral measurements along with time domain analyses up to frequencies of 400 kHz. All probes have a digital interface that transmits the measurement data to the basic device in a fail-safe manner. This eliminates the need to calibrate the basic unit. The FieldMan is available in several device variants: fully equipped, as an RF variant, as an LF variant, with voice recording or a radio-free device without a microphone. The RF and LF variants can be upgraded with the Data Logger software option for data storage.

Non-directional measurement using isotropic probes for applications in the frequency range 0 Hz (DC) to 90 GHz Large sunlight readable color display 5” diagonal with 1280x720 HD resolution Digital probe interface for broadband and selective probes – no more meter calibration Powerful time and frequency domain analysis for low frequency fields up to 400 kHz including Weighted Peak measurements Variant with optional WiFi / Bluetooth interface for remote control via smartphone app Built-in GPS receiver and rangefinder for easy location determination (Option) Fast data transmission optical interface Ethernet USB-C NSTS 0925-E0370EE ᅵ Narda FieldMan Datasheet ᅵ Subject to change without notice www.narda-sts.com 1 / 10

Стр. 1

Applications Digital Probes The Narda FieldMan is used to make precision measurements to establish human safety, particularly in workplace environments where high electric or magnetic field strengths are likely to occur. An essential task is to demonstrate compliance with general safety regulations, such as FCC, IEEE, ICNIRP or EMF Directive 2013/35/EU. Examples of measurement environments are: A large number of isotropic field probes are available for the FieldMan. All of them transmit their information and measurement data as a digital signal to the FieldMan, either via an electrical USB interface or via an optical COM interface.

In this way, interference is significantly reduced compared to high-resistance analog interfaces. The specially developed screw connectors and electrical contacts are extremely robust and resilient. Radiocommunication base stations (e.g. IEC / EN 62232) Broadcasting systems (e.g. IEC 62577) Radar and satellite communications systems Induction heating and melting (e.g. EN 50519) Household appliances (e.g. IEC / EN 62233) Electric welding equipment (e.g. IEC / EN 62822) Railroad operations (e.g. EN 50500) Automotive operations (e.g. IEC 62764) Energy supply systems (e.g. IEC / EN 62110) Electrical medical devices (e.g.

IEC / EN 60601) TEM cells and absorber chambers to demonstrate electromagnetic compatibility (EMC) The probes are automatically recognized after connection to the FieldMan. Sensors inside the probe record the temperature of the measuring location and transmit it to the FieldMan display. In addition to the automatic offset correction, the temperature measurement is also used to compensate for the typical temperature dependency of the sensor diodes. The advantages are uninterrupted measurements without zero adjustment and higher measurement accuracy over wide temperature ranges.

An automatic self-test function can even detect possible errors in the sensor system, which means that additional checking with a test generator is superfluous. Only the digital probes are calibrated. You can continue to use your FieldMan during this time. There are probes for many different applications with the appropriate frequency and level ranges. The following table gives an overview of common areas of application. Fig. 1.

Areas of application and suitable probe models NSTS 0925-E0370EE ᅵ Narda FieldMan Datasheet ᅵ Subject to change without notice www.narda-sts.com 2 / 10 Frequency range DC up to Up to Up to Up to 30 MHz Up to Up to Up to Up to Up to 1 kHz 400 kHz 400 kHz 1 GHz 6 GHz 40 GHz 90 GHz 50 GHz Field type, magnetic (H) or electric (E) H E+H H H H E E E E Shaped Probe models LF – variant RF – variant BFD-400-1 EFD-0391 EAD-5091 EFD-5091 (100 cm2) EFD-0392 EFD-1891 EBD-5091 HP-01 EHP-50F/G BFD-400-3 HFD-3061 HFD-0191 EFD-0691 EFD-4091 EFD-6091 ECD-5091 EFD-9091 (3 cm2) EFD-0692 EDD-5091 5G mobile radio / telecommunications       Broadcast radio / TV      Satellite communications    Radar    Industry:

Heating and tempering   Industry: Plastics welding   Industry: Semiconductor production   Medicine: Diathermy, hyperthermy   Leak location    Household appliances  Electric welding equipment   Railroad operations    Automotive operations   Energy supply systems   Electric medical devices    Accredited calibration included      Probe interface Optical connection Digital probe interface

Стр. 2

Use and benefit Status LED Probe connection During the development of the FieldMan, special attention was paid to achieving simple, well-structured and fluid operation. The arrangement of many display elements known from smartphones, the self-explanatory symbols and the FieldMan processes, which are perfectly tailored to the measurement tasks, offer maximum ease of use. The large, anti-glare HD color display shows the measured values numerically and graphically with all important additional information in a clear form and is easy to read even in bright sunlight.

From simple broadband measurements to sophisticated time signal recording in real time or spectral frequency analysis of low-frequency fields, you have the right operating modes at your disposal. Brightness sensor Loudspeaker Microphone*, humidity sensor Status bar Position Probe information Measurement information Measurement isotropic Measurement single axes Measurement results can be commented on by text or voice* and can be saved as a screen copy at the push of a button. Built-in sensors record the current environmental conditions as well as the position data and automatically add them to the measurement result.

The built-in distance meter (option) shows you the measuring height above the ground, which makes the exact positioning of the measuring device much easier. For a better overview, the measurement results can be assigned to freely definable projects, which is particularly helpful when the measurement locations change frequently. If you want to document your measurement results with photos and videos, the FieldMan smartphone app will help you. For example, the app wirelessly* transfers media files created with the smartphone to the project directory on the FieldMan’s memory card or internal memory.

A newly developed, extremely powerful PC software "Narda-TSX" is available for documenting the measurement results, media and other information. It is Narda's new software platform for device configuration, measurement data evaluation and documentation, which in addition to the FieldMan will also support other Narda products in the future. * depending on the device variant Statistical values Interface panel Measurement graphic: Time curve, spectrum or bar graph Softkey symbols Softkeys Save key Back key Navigation key Fig. 2. FieldMan display and controls Fig. 3.

The FieldMan is supplied with a robust transport case NSTS 0925-E0370EE ᅵ Narda FieldMan Datasheet ᅵ Subject to change without notice www.narda-sts.com 3 / 10

Стр. 3

Definitions and Conditions Specifications 1 The permissible operating range of the device and probe must not be exceeded. The temperature sensor is located in the probe. NSTS 0925-E0370EE ᅵ Narda FieldMan Datasheet ᅵ Subject to change without notice www.narda-sts.com 4 / 10 Conditions Unless otherwise noted, specifications apply within the specified environmental conditions. The product is within the recommended calibration cycle. Specifications with limits These describe product performance for the given parameter covered by warranty.

Specifications with limits (shown as , ≥, ±, max., min.) apply under the given conditions for the product and are tested during production, considering measurement uncertainty. Specifications without limits These describe product performance for the given parameter covered by warranty. Specifications without limits represent values with negligible deviations, which are ensured by design (e.g. dimensions or resolution of a setting parameter). Typical values (typ.) These characterize product performance for the given parameter that is not covered by warranty.

When stated as a range or as a limit (shown as , ≥, ±, max., min.), they represent the performance met by approximately 80% of the instruments. Otherwise, they represent the mean value. The measurement uncertainty is not taken into account. Nominal values (nom.) These characterize expected product performance for the given parameter that is not covered by warranty. Nominal values are verified during product development but are not tested during production. Uncertainties These characterize the dispersion of the values attributed to the measurands with an estimated confidence level of approximately 95%.

Uncertainty is stated as the standard uncertainty multiplied by the coverage factor k=2 based on the normal distribution. The evaluation has been carried out in accordance with the rules of the “Guide to the Expression of Uncertainty in Measurement” (GUM). Metrics Electric and magnetic fields Measurement control and result display for the following probes and analyzers. Frequency range and level range depending on the probe/ analyzer.

Broadband probes 100 kHz to 90 GHz (see list of digital broadband probes) Selective probes 1 Hz to 400 kHz, B-field (see list of digital selective probes) Probe model EHP-50F/G 1 Hz to 400 kHz, E-field and B-field (FFT-Analyzer, see separate datasheet) Probe model HP-01 0 Hz to 1 kHz, B-field (Magnetometer/ FFT-Analyzer, see separate datasheet) Electric field units V/m, mW/cm2, W/m2, % of standard (depending on the connected probe) Magnetic field units A/m, Tesla, Gauss, mW/cm2, W/m2, % of standard (depending on the connected probe) Temperature 1 Logging of the ambient temperature at the time of measurement (-40 °C to +85 °C) in °C or °F Humidity 1 Logging of the ambient relative humidity at the time of measurement (0% to 100% RH) Air pressure Logging of the ambient air pressure at the time of measurement (300 to 1100 hPa) Distance (Option) An ultrasonic rangefinder on the bottom side measures the distance to ground or to an object (0.25 m to 4 m) in m, ft, in or yd.

Coverage ratio ≈ Distance / 4. Geolocation (Option) Built-in GNSS receiver for determining latitude, longitude and altitude (MSL). 72 channels with the support of GNSS systems (GPS / QZSS, Galileo, GLONASS, BeiDou) and the SBAS extension system (WAAS, EGNOS, MSAS, GAGAN). Position accuracy: Autonomous 2.5 m CEP. Display Display type Sunlight readable 5” color TFT-LCD anti-glare display (HD 1280 x 720 pixels) Brightness Manual control or automatic control via brightness sensor Operating languages Largely language-independent measurement control via symbols. Menu languages: English, German, more are planned.

Стр. 4