SPRUT — ANALYSIS AND DESIGN OF FLAT SLABS USING VARIOUS CODES

EURODODE Introduction This Eurocode gives all structural design irrespective of the material of construction. It establishes principles and requirements for safety, ser viceability and durability of structures The Eurocode uses a statistical approach to determine realistic values for actions that occur in combination with each other. Partial fa ctors for actions are given in this Eurocode, whilst partial factors for materials are prescribed in their relevant Eurocode. It is again divided into different codes based on the materials. In this Eurocode2 gives the design of concrete structures. EUROCODE 2 1. Eurocode 2 is generally laid out to give advice on the basis of p henomena (e.g.

bending, shear etc) rather than by member types as in BS 8110 (e.g. beams, slabs, columns etc). 2. Design is based on characteristic cylinder strengths not cube strengths. 3. The Eurocode does not provide derived formulae (e.g. for bendi ng, only the details of the stress block are expressed). This is the traditional European approach, where the application of a Eurocode expected to be provided in a textbook or similar publication. 4. Units for stress are mega pascals, MPa (1 MPa = 1 N/m m 2 ). 5.Higher strengths of concrete are covered by Eurocode 2, up to class C90/105.

However, because the characteristics of higher strength concrete are different, some Expressions in the Eurocode are adjusted for classes above C50/60. 6. The partial factor for steel reinforcement is 1.15. However, the characteristic yield strength of steel that meets the requirements of BS 4449 will be 500 MPa; so overall the effect is negligible. Eurocode 2 is applicable for ribbed reinforcement with characteristic yield strengths of 400 to 600 MPa. There is no guidance on plain bar or mild steel reinforcement in the Eurocode, but guidance is given in the background paper to the UK National Annex10. 7. Minimum concrete cover is related to bond strength, durability and fire resistance.

In addition to the minimum cover an allowance for deviations due to variations in execution (Construction) should be included. Eurocode 2 recommends that, for concrete cast against formwork, this is taken as 10 mm, unless the construction is subject to a quality assurance systemic which case it could be reduced to 5 mm or even 0 mm whereon -conforming members are rejected (e.g. in a precast yard). 8. The punching shear checks are carried at 2 d from the face of the column and for a rectangular column, the perimeter is rounded at the corners. 30