Conclusions : By comparing with different codes we concluded that ACI 318, NZS 3101& euro codes are most effective in designing of flat slabs. As per Indian code we are using cube strength but in international standards cylindered are used which gives higher strength than cube. Drops are important criteria in increasing the shear strength of the slab. Enhance resistance to punching failure at the junct ion of concrete slab & column. By incorporating heads in slab, we are increasing rigidity of slab. In the interior span, the total design moments (Mo) are same for IS, NZS, ACI.
The negative moment’s section shall be designed to resist the larger of the two interior negative design moments for the span framing into common supports. According to Indian standard (IS 456) for RCC code has recommended characteristic strength of concrete as 20, 25, and 30 and above 30 for high strength concrete. For design purpose strength of concrete is taken as 2/3 of actual strength this is to compensate the difference between cube strength and actual strength of concrete in structure. After that we apply factor of safety of 1.5. So in practice Indian standard actually us es 46% of total concrete characteristic strength.
While in International practice is to take 85% of total strength achieved by test and then apply factor of safety which is same as Indian standard so in actual they use 57% of total strength. Pre fabricated sections to be integrated into the design for ease of construction. 52