Supermicro A+ Server 1122GG-TF — Supermicro A+ Server 1122GG-TF User's Manual PDF Download

A+ Server 1122GG-TF User's Manual Flow Control Selects the flow control to be used for console redirection. Options are None, Hardware and Software. Redirection After BIOS POST This option sets redirction after BIOS POST. Options are Disable (no redirection after BIOS POST), Boot Loader (redirection during POST and during boot loader) and Always (redirection always active). Note that some OS's may not work with this set to Always. Terminal Type Selects the type of the target terminal. Options are ANSI , VT100 and VT-UTF8. VT-UTF8 Combo Key Support Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/ VT100 terminals.

Sredir Memory Display Delay Use this setting to set the delay in seconds to display memory information. Options are No Delay , 1 sec, 2 secs and 4 secs. Hardware Health Configuration CPU Overheat Alarm This setting allows you to specify the type of alarm for CPU overheating. Options include The Early Alarm and The Default Alarm . Fan Speed Control This feature allows the user to determine how the system will control the speed of the onboard fans. The options are Full Speed/FS (Max Cooling), Performance/ PF (Better Cooling), Balanced/BL (Balance between performance and energy saving), Energy Saving/ES (Lower Power and Noise).

Other items in the submenu are systems monitor displays for the following information: CPU 1 Temperature, CPU 2 Temperature, System Temperature, Air Tempera­ ture, Fan 1-8 Reading, CPU 1 VCore, CPU 2 VCore, CPU 1 DDR3 Memory, CPU 2 DDR3 Memory, CPU 1 Memory Vref 0.75V, CPU 2 Memory Vref 0.75V, SR5690 Core Power P1V1, 1.8V, 5V, 12V, 3.3V, 3.3V STB, Battery 3.0V and CPU 1 1.2V. 7-16