A+ Server 1122GG-TF User's Manual 3-2 Control Panel Buttons There are two power control push-buttons on the front of the chassis. Reset Use the reset button to reboot the system. Power The main power button is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system. 3-3 Control Panel LEDs The control panel displays five LEDs that indicate the status of the system. Information LED Alerts operator of several states, as noted in the table below. 3-2 Information LED Status Description Continuously on and red An overheat condition has occured.
(This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan. Blinking red (0.25Hz) Power failure, check for a non-operational power supply. Solid blue Local UID has been activated. Use this function to locate the server in a rack mount environment. Blinking blue Remote UID is on. Use this function to identify the server from a remote location.