A+ SERVER 2122TC-H6RF4 USER'S MANUAL Chassis SC217HQ-R1620BP (2U rackmount) Dimensions: (WxHxD) 17.25 x 3.47 x 28.5 in. (438 x 88 x 724 mm) Weight Gross (Bare Bone): 85 lbs. (38.6 kg.) System Cooling Four 8-cm PWM system cooling fans System Input Requirements AC Input Voltage: 85-264V AC auto-range Rated Input Current: 15 - 5A Rated Input Frequency: 47 to 63 Hz Efficiency: 94+ (Platinum Level) Power Supply Rated Output Power: 1620 Watts (Part# PWS-1K62P-1R) Rated Output Voltages: +12V (135A@180-264V, 100A@120-140V), +5Vsb (6A) Operating Environment Operating Temperature: 10є to 30є C (50є to 86є F) Non-operating Temperature: -40є to 70є C (-40є to 158є F) Operating Relative Humidity:

20% to 95% (non-condensing) Non-operating Relative Humidity: 5 to 95% (non-condensing) Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3- 3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.

See www.dtsc.ca.gov/hazardouswaste/perchlorate” for further details. B-2