A+ SERVER 2122TC-H6RF4 USER'S MANUAL 4. Remove the add-on card brackets: 4a. Remove screw securing the add-on card bracket to the back of the node drawer. 4b. Lift the bracket out of the node drawer. 5. Make sure that the I/O ports on the serverboard align properly with their respective holes in the I/O shield at the back of the node drawer. 6. Lay the motherboard in the node drawer aligning the standoffs with the motherboard. 7. Secure the motherboard to the node drawer using the rounded, Phillips head screwsusing no more than 8 inch-lbs of torque. 8. Install the adapter card associated with the motherboard. Refer to the next section for instructions on installing the adapter card 9.

Secure the CPUs, heatsinks, and other components to the motherboard as described in the motherboard documentation. 10. Connect the cables between the motherboard, backplane, chassis, front panel, and power supply, as needed. Also, fans may be temporarily removed to allow access to the backplane ports. 11. Replace the add-on card bracket and secure the bracket with a screw. 12. Repeat for the remaining nodes. 13. Connect the AC power cord and power up the system. Figure 6-11. Installing the Motherboard in the Node Drawer Note : The node drawing is an example only, actual layout differs slightly. 6-12