Chapter 5: Advanced Chassis Setup 5-3 System Fans System cooling is provided by three sets of counter-rotating fans at the front of each expander. Each fan assembly (one for each node) consists of three sets of counter-rotating fans. The counter-rotating action helps dampen vibration levels while generating exceptional airfl ow. It is very important that the chassis cover is properly installed and making a good seal for the cooling air to circulate properly through the chassis and cool the com- ponents. System Fan Failure Fan speed is controlled by system temperature via an expander.
If a fan fails, the remaining fans will ramp up to full speed and the overheat/fan fail LED on the control panel (of the same side as the failed fan) will turn on. The counter-rotating fans may also be visually inspected for failure. Replace any failed fan at your earli- est convenience with the same type and model (the system can continue to run with a failed fan). Remove the top chassis cover while the system is still running to determine which of the fans has failed. Replacing System Fans Replace the failed fan with an identical 4-cm, 12-volt counter-rotating fan (p/n FAN- 0088L4, available from Supermicro). See Figures 5-2 and 5-3.
Replacing Fans Shutdown the node with the failed fan(s) and remove the AC power cord. 1. On the node with the failed fan, push the release bar down to unlock the 2. serverboard tray. Use the bar to pull the node/serverboard from the chassis. 3. Remove the failed fan from the assembly and replace it with an identical 4. replacement. You may need to remove the assembly to replace the lower fan. Slide the serverboard tray back into the chassis. When seated, lift the release 5. bar to lock it into place. Reconnect the AC power cord and power up the node. 6. Inspect the replaced fan to verify it is working. 7. 5-3