Supermicro A+ Server 1012A-MTF — Supermicro A+ Server 1012A-MTF — User's Manual

A+ Server 1012A-MTF User's Manual Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions. Overheat (OH)/Fan Fail/PWR Fail/UID LED Connect an LED cable to pins 7 and 8 of JF1 to use the Overheat/Fan Fail/Power Fail and UID LED connections. The Red LED on pin 8 provides warnings of an overheat, fan failure or power failure. The Blue LED on pin 7 works as the UID LED indicator for the front panel UID switch located on pins 8 of JF1. When Jumper J_UID_OW is set to off (default), the Red LED takes precedence over the Blue LED. (See Page 2-19 for de­ tails.) Refer to the table on the right for pin definitions.

NIC2 (LAN2) LED Connections The LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to display network activity. See the table on the right for pin definitions. NIC1 (LAN1) LED Connections The LED connections for LAN1 are on pins 11 and 12 of JF1. Attach LAN LED cables to display network activity. See the table on the right for pin definitions.

5-12 PWR Fail LED Pin Definitions (JF1) Pin# Definition 5 3.3V 6 PWR Fail LED OH/Fan Fail/ PWR Fail/Blue UID _ LEDPin Defi nitions (JF1) Pin# Definition 7 Blue LED-Cathode (UID)/5.5V.SB _ 8 OH/Fan Fail/PWR Fail/UID LED (Red) OH/Fan Fail/PWR Fail LED Status (Red LED) State Indication Off Normal On Overheat Flashing Fan Fail NIC2 LED Pin Definitions (JF1) Pin# Definition 9 Activity 10 Link NIC1 LED Pin Definitions (JF1) Pin# Definition 11 Activity 12 Link