Chapter 2: Server Installation 2-6 Checking the Serverboard Setup After you install the server in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. Removing the Chassis Cover 1. Release the retention screws that secure the unit to the rack. 2. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). 3. Remove the screws from the chassis cover (see Figure 2-5). 4. Release the top cover by pushing it away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server Checking the Components 1.
You may have processors already installed into the serverboard. Each processor should have its own heatsink attached. See Chapter 5 for instructions on processor installation. 2. The A+ Server 1012C-MRF server may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5. 3. If desired, you can install an extension card to the system. See Chapter 5 for details on installing a PCI extension card. 4. Make sure all power and data cables are properly connected and not blocking the airflow. See Chapter 5 for details on cable connections. Also, check that the air shroud is properly installed. 2-9