Chapter 4: System Safety Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions. Overheat/Fan Fail LED (OH) Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure. Refer to the table on the right for pin definitions and status indicators. NIC2 (LAN2) LED The LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to display network activity. See the table on the right for pin definitions. NIC1 (LAN1) LED The LED connections for LAN1 are on pins 11 and 12 of JF1. Attach LAN LED cables to display network activity.
See the table on the right for pin definitions. HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. Attach the hard drive LED cable here to display disk activity (for any hard drives on the system, including SAS, Serial ATA and IDE).
See the table on the right for pin definitions 5-13 PWR Fail LED Pin Definitions (JF1) Pin# Definition 5 3.3V 6 Power Fail LED OH/Fan Fail LED Pin Definitions (JF1) Pin# Definition 7 Vcc 8 OH/Fan Fail (Red) LED OH/Fan Fail LED Status State Indication Solid Overheat Blinking Fan fail NIC2 LED Pin Definitions (JF1) Pin# Definition 9 Activity 10 Link NIC1 LED Pin Definitions (JF1) Pin# Definition 11 Activity 12 Link HDD LED Pin Definitions (JF1) Pin# Definition 13 Vcc 14 HD LED