Supermicro SuperServer 1015B-M3 — Supermicro SuperServer 1015B-M3 User's Manual PDF (Revision 1.0)

S UPER S ERVER 1015B-M3 Manual 3-3 Control Panel LEDs The control panel located on the front of the SC113MTS-560C chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Universal Information LED When this LED blinks red quickly, it indicates a fan failure and when blinking red slowly a power failure. This LED will be blue when used for UID (Unit Identifi er).

When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airfl ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing or on as long as the indicated condition exists. See the table below for descriptions of the LED states. Figure 3-1. Universal Information LED States Note: deactivating the UID LED must be performed in the same way it was activated.

IPMI is not supported on the X7SB3. 3-2 Universal Information LED States State Indication Fast Blinking Red (1x/sec) Fan Fail Solid Red CPU Overheat Slow Blinking Red (1x/4 sec) Power Fail (1025W-UR only) Solid Blue Local UID Button Depressed Blinking Blue IPMI-Activated UID