Supermicro SuperServer 1015B-M3 — Supermicro SuperServer 1015B-M3 User's Manual PDF (Revision 1.0)

Chapter 5: Advanced Serverboard Setup SMBus to PCI Slots Jumpers JI 2 C1 and JI 2 C2 allow you to connect the System Management Bus (I 2 C) to the PCI-E/PCI slots. The default setting is Open (Disabled.) Both jumpers must be set to the same setting (JI 2 C1 controls the clock and JI 2 C2 controls the data). See the table on the right for jumper settings. SAS Enable/Disable JPS1 allows you to enable or disable SAS ports. The default position is on pins 1 and 2 to enable SAS. See the table on the right for jumper settings. SAS RAID Mode Select JPS2 allows you to select the SAS RAID mode: either Software RAID or IT RAID. Close this jumper to use Software RAID (default).

Set this jumper to open to use the IT RAID mode. Contact Tech. Sup- port at Supermicro for more information. See the table on the right for jumper Note: Contact Supermicro tech support for further instructions. settings. Power Force On Jumper JPF allows you to enable or disable the Power Force On function. If enabled, system power will always stay on. If disabled (the normal setting), the user needs to press the power button to power on the system. 5-21 SMBus to PCI Slots Jumper Settings (JI2C1/JI2C2) Jumper Setting Defi nition JI2C1: Closed JI2C2:Closed Enabled JI2C1: Open JI2C2:

Open Disabled SAS Enable/Disable Jumper Settings (JPS1) Jumper Settings Defi nition Pins 1-2 Enabled (Default) Pins 2-3 Disabled SAS RAID Mode Select Jumper Settings (JPS2) Jumper Settings Defi nition Closed Enabled (Default) Open* IT Mode Enabled Power Force On Jumper Settings (JPF) Jumper Setting Defi nition Closed Force On Open Disabled