Supermicro SuperServer 1015B-M3 — Supermicro SuperServer 1015B-M3 User's Manual PDF (Revision 1.0)

S UPER S ERVER 1015B-M3 User's Manual Console Connection This item allows you to decide how console redirection is to be connected: either Direct or Via Modem. Continue CR after POST Select on to continue with console redirection after the POST routine. The options are On and Off . X Hardware Monitoring Highlight an item and hit to see the status of the item: CPU Temperature/TControl/CPU1 Temperature/System Temperature Fan1 - Fan 6 If the feature of Auto Fan Control is enabled, the BIOS will automatically display the status of the fan as specifi ed. Fan Speed Control Modes This feature allows the user to decide how the system controls the speeds of the onboard fans.

The CPU temperature and the fan speed are correlative. When the CPU on-die temperature increases, the fan speed will also increase, and vice versa. Select Workstation if your system is used as a Workstation. Select Server if your system is used as a Server. Select 3-pin if your chassis uses 3-pin fans. Select 4-pin if your chassis uses 4-pin fans. Select “Disable” to disable the fan speed control function and allow the onboard fans to constantly run at the full speed (12V). The Options are: 1. Full Speed @12V, 2. Optimized Server w/3-pin, 3. Optimized Workstation w/3-pin, 4. Optimized Server w/4-pin, and 5. Optimized Workstation w/4-pin.

Voltage Monitoring The following items will be monitored and displayed: VcoreA, -12V/+12V, V_DIMM, +3.3V/+3.3Vsb, Vbatt. Note: In the Windows OS environment, the Supero Doctor III settings take prece- dence over the BIOS settings. When fi rst installed, Supero Doctor III adopts the temperature threshold settings previously set in the BIOS. Any subsequent changes to these thresholds must be made within Supero Doctor, since the SD III settings override the BIOS settings. For the Windows OS to adopt the BIOS temperature threshold settings, please change the SDIII settings to be the same as those set in the BIOS. 7-16