Supermicro 1018D-73MTF — SUPERSERVER 1018D-73MTF — User's Manual

S UPER S ERVER 1018D-73MTF User's Manual H/W (Hardware) Monitor PC Health Status Fan Speed Control Mode This feature allows the user to decide how the system controls the speeds of the onboard fans. The CPU temperature and the fan speed are correlative. When the CPU on-die temperature increases, the fan speed will also increase for effective system cooling. Select "Full Speed" to allow the onboard fans to run at full speed (of 100% Pulse Width Modulation Duty Cycle) for maximum cooling. This setting is recommended for special system configuration or debugging.

Select "Standard" for the onboard fans to run at 50% of the Initial PWM Cycle in order to balance the needs between system cooling and power saving. This setting is recommended for regular systems with normal hardware configurations. The options are Full Speed (@100% of PWM Cycle) and Standard (@50% of PWM Cycle). The following items will be displayed: CPU Temperature (PECI) Front Side Sys. (System) Temperature Rear Side Sys. (System) Temperature PCH Temperature Fan1 Speed/Fan2 Speed/Fan3 Speed/Fan4 Speed/Fan5 Speed VCORE 12V VDIMM 5Vcc PCH 1.05V AVCC 3.3Vcc VSB VBAT 7-24