S UPER S ERVER 1018D-73MTF Manual 2-4 Installing the System into a Rack This section provides information on installing the SuperServer 1018D-73MTF into a rack. If the 1018D-73MTF has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. Note: The rails will fit a rack between 26" and 33.5" deep. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the 1018D- 73MTF into a rack with the rack rails provided. You should also refer to the instal lation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails Each assembly consists of two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself. Figure 2-1. Identifying the Sections of the Rack Rails Inner Rail Extensions Inner Rails Warning: do not pick up the server with the front handles. They are de signed to pull the system from a rack only. 2-4