S UPER S ERVER 1018D-FRN8T Manual Chapter 6: Advanced Chassis Setup 6-6 Installing Expansion Cards 5-9 Power Supply Expansion Card The SC515-R407 chassis has a redundant (two) 400W hot-swappable power supplies. The power supplies are auto-switching capable. This enables it to automatically sense and operate at a 100v to 240v input voltage. If your system has a fixed power supply, it will be necessary to shut down the system in order to change the power supply. If your system includes a redundant power supply, it is hot-swappable and can be changed without powering down the system.
Expansion Card Bracket Changing a Redundant Hot-Swap Power Supply In the event that one of the power supplies fails, the redundant power supply will take over. Replacing the power supply is simple and requires no tools. Replacing the Power Supply 1. Push the release button on the failed power supply. Riser Card 2. Pull the power supply out using the handle. Figure 6-7. Installing an Expansion Card with Bracket 3. Replace the power supply with another of the same model and push it into the chassis until it clicks into the locked position. Installing an Expansion Card 1. Confirm that you have the correct riser card for your chassis model and that the expansion card includes a standard bracket.
2. Power down the system and open the chassis cover as described in Section 6-3. 3. Remove the riser card bracket from the chassis. Release Button 4. Attach the riser card to the riser card bracket with screws. 5. Insert the expansion card(s) into the riser card slot(s). Figure 6-8. Removing a Hot-Swap Redundant Power Supply 6. Insert the riser card into the serverboard's expansion slot while aligning the expansion card bracket with the openings in the rear of the chassis. 7. Secure the riser card bracket to the chassis and the expansion card bracket to the rear of the chassis. 8. Replace the chassis cover and power up the system. 6-7 6-6