Supermicro SuperServer 1019S-M2 — Installing the Server into a Telco Rack

SuperServer 1019S-M2 User's Manual Chapter 2: Server Installation Installing the Server into the Rack Installing the Server into a Telco Rack 1. Align the chassis rails with the front of the rack rails. Optional brackets (p/n MCP-290-00016-0N) are needed to install the server to a Telco (two post type) rack. Use the two L-shaped brackets on either side of the chassis (four total). 2. Slide the chassis rails into the rack rails, keeping the pressure even on both sides. The spring latch engages when the chassis is part way in. Push the server completely into the rack. 1. First, determine how far follow the server will extend out the front of the rack.

Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. 3. ( Optional ) Insert and tighten the thumbscrews that hold the front of the server to the rack. 2. Attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the telco rack. 3. Finish by sliding the chassis into the rack and tightening the brackets to the rack. Figure 2-3. Installing the Server into a Rack Figure 2-4. Installing the Server into a Telco Rack Note: Figure is for illustrative purposes only. Always install servers to the bottom of a rack first. Note: