SuperServer 1019S-M2 User's Manual Chapter 3: Maintenance and Component Installation 3.4 Chassis Components Hard Drives The 1019S-M2 supports two fixed 2.5" hard disk drives with the use of a hard drive bracket (included with the system). Installing Hard Disk Drives 1. Identify the HDD bracket and secure the drive(s) to the bracket. (Figure 3-11). 2. Secure the HDD bracket to the chassis floor. (Figure 3-12). 3. Connect the drive cabling. Bracket Hard Drive Figure 3-12. Securing the HDD Bracket to the Chassis Floor System Fans Figure 3-11. Installing Hard Drives into the Bracket The SC514 chassis includes four heavy-duty fans for system cooling plus the option to add two additional fans.
Replacing a System Fan Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www. supermicro.com/products/nfo/files/storage/SBB-HDDCompList.pdf 1. If necessary, open the chassis cover while the power is running to determine which fan requires changing. (Do not run the server for an extended time with the chassis open.) 2. Power down the system as described in section 3-1. 3. Remove the cables of both the failed fan and the other fan sharing the same tray (since two fans occupy one housing). 4. Lift the fan housing with the two fans attached up and out of the chassis.
Remove the failed fan by gently pulling it out of the housing. 5. Place the new fan into the vacant space in the housing. Make sure that the arrows on the sides of the fan (indicating air direction) point in the same direction as the arrows on the other fans. 6. Plug the fan cable into the connector on the serverboard. 35 34