Supermicro SuperServer 1019S-M2 — Control Panel

Chapter 4: Motherboard Connections SuperServer 1019S-M2 User's Manual Reset Button NIC1/NIC2 (LAN1/LAN2) The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case. The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on Pins 9 and 10. Attach the NIC LED cables here to display network activity. Power Fail LED HDD LED The Power Fail LED connection is located on pins 5 and 6 of JF1. The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable here to indicate the status of all HDD-related activity.

Overheat (OH)/Fan Fail Connect an LED cable to pins 7 and 8 of JF1 to use the Overheat/Fan Fail LED connections.. Power LED The Power LED connection is located on pins 15 and 16 of JF1. 47 46 Reset Button Pin Definitions (JF1) Pin# Definition 3 Reset 4 Ground LAN1/LAN2 LED Pin Definitions (JF1) Pins Definition 9/11 +3.3V Stby 10/12 LANLED Active Power Fail LED Pin Definitions (JF1) Pin# Definition 5 3.3V 6 PWR Supply Fail HDD LED Pin Definitions (JF1) Pins Definition 13 +3.3V Stby 14 HD Active OH/Fan Fail Indicator Status Status Definition Off Normal On Overheat Flashing Fan Fail Power LED Pin Definitions (JF1) Pin# Definition 15 3.3V Standby 16 Power LED