Supermicro SuperServer 1019S-WR — Power Supply

SuperServer 1019S-WR User's Manual Chapter 3: Maintenance and Component Installation 7. Place the fan housing into the chassis and secure it with the screws previously set Power Supply aside. The 1019S-WR has a redundant 400W power supply to provide power redundancy. The power supplies has an auto-switching capability, which enables them to automatically sense and operate at a 100V-240V input voltage. 8. Power up the system and check that the fan is working properly before replacing the top cover. Checking the Server Airflow If a power supply unit fails, it can be changed without powering down the system. Replacement units can be ordered directly from Supermicro.

Changing a Power Supply Make sure there are no objects to obstruct airflow in and out of the server. Make sure no cables or foreign objects obstruct airflow through the chassis. Pull all excess cabling out of the airflow path or use shorter cables. 1. Press the release button on the failed power supply. 2. Use the handle to gently slide the power supply out the back of the chassis. 3. Replace the failed power module with another of the same model. 4. Slide the new power supply module into the power supply bay until it clicks into the locked position. 5. Reconnect the AC power cord to the power supply. Figure 3-13. Replacing a System Fan Release Button Figure 3-15.

Replacing a Power Supply Module Figure 3-14. Removing a Fan from the Fan Housing 37 36