Chapter 3: System Interface Overheat/Fan Fail/UID LED When this LED fl ashes it indicates a fan failure. When continuously on (not fl ashing) it indicates an overheat condition, which may be caused by cables obstructing the airfl ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure that all fans are present and op- erating normally. Also check to make sure that the air shrouds are installed and that the top cover is on. Finally, verify that the heatsinks are installed properly. This LED will remain fl ashing or on as long as the overheat condition exists.
When used with a UID-compatible motherboard, the UID function is used to turn on or off the blue light function of the the LED. Once the blue light is activated through the system software, the unit can be easily located in very large racks and server banks. 3-4 Hard Drive Carrier LEDs Each hard drive carrier has two LEDs. Green: When illuminated, the green LED on the front of the drive carrier in- dicates drive activity. A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed. Red: The red LED indicates two states. When blinking, it indicates the drive is rebuilding. When solid, it indicates a drive failure.
If a drive fails, you should be notifi ed by your system management software. Please refer to Chapter 6 for instructions on replacing failed drives. 3-3