Chapter 5: Advanced Serverboard Setup I 2 C Bus to CPU1/CPU2 VRMs Use Jumpers JVRM_I 2 C1/JVRM_I 2 C2 to connect the System Management Bus (I 2 C) to the CPU1/CPU2 VRMs. The default setting for the is on pins 1-2 to enable the connection. See the tables on the right for jumper settings. LAN Port Enable/Disable Use JPL1/JPL2 to enable or disable LAN Ports 1 and 2 on the serverboard. See the table on the right for jumper settings. The default setting is enabled. BMC Enable/Disable JPB1 is used to enable or disable the BMC (Baseboard Management Control) chip to provide IPMI 2.O/KVM support. The default position is on pins 1 and 2 to Enable BMC. See the table on the right for jumper settings.
Watch Dog Enable Watch Dog is a system monitor that can reboot the system when a software appli- cation hangs. Close pins 1-2 of JWD1 to reset the system if an application hangs. Close pins 2-3 to generate a non-mask- able interrupt signal for the application that hangs. See the table on the right for jumper settings. Watch Dog must also be enabled in the BIOS.
5-21 I2C to VRMs (for X9DBL-3F/iF) Jumper Settings Jumper Setting Defi nition Pins 1-2 Enabled (Default) I2C to VRMs (for X9DBL-3/i) Jumper Settings Jumper Setting Defi nition Pins 2-3 Enabled (Default) LAN Port En/Disable Jumper Settings Setting Defi nition 1-2 Enabled 2-3 Disabled BMC IPMI Enable/Disable Jumper Settings Setting Defi nition Pins 1-2 Enabled Pins 2-3 Disabled Watch Dog Jumper Settings Setting Defi nition Pins 1-2 Reset (default) Pins 2-3 NMI Open Disabled