Chapter 6: Advanced Chassis Setup 6-6 Installing the Air Shrouds Air Shrouds Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC217 chassis air shroud does not require screws to set up. Two identical air shrouds are required, one in each serverboard drawer. Installing an Air Shroud Confi rm that all four fans are in place and working properly 1. Place the fi rst air shroud into the serverboard drawer so that it sits behind the 2. system fans and goes over the top of the serverboard and its components. Repeat the procedure for the remaining serverboard drawer. 3.
6-7 Power Supply The 2026TT-DLRF/DLIBXRF/DLIBQRF server has two 1400 watt power supply modules to provide redundant power for the system. If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption. The LED on the control panel will fl ash slowly (about 4 seconds on and 4 off) and remain fl ashing until the failed unit has been replaced. Replacement units can be ordered directly from Supermicro (see contact information in the Preface). The power supply units have a hot-swap capability, meaning you can replace the failed unit without powering down the system.
Removing/Replacing the Power Supply (Figure 6-8) Disconnect the AC power cord from the failed module. 1. Push the colored release tab to the side and pull the power module out with 2. the handle provided. Replace the failed power supply module with the exact same model from 3. Supermicro. Carefully insert the new module into position in the chassis and push it in until 4. fully seated. You should see the LED on the rear of the module turn amber showing that power (from the backup module) is present. Reconnect the AC power cord to the new module. 5. 6-9