Supermicro — 2028TP-DECR-DECTR-DECFR_1.0.indb

Chapter 3: System Interface Information LED See the following table for the status shown by this LED. 3-4 Drive Carrier LEDs The chassis includes externally accessible SAS/SATA drives. Each drive carrier displays two status LEDs on the front of the carrier. 3-3 Information LED Status Description Continously on and red An overheat ocondition has occured. (This may be caused by cable congestion.) Blinking red (1 Hz) Fan failure: check for an inoperative fan. Blinking red (0.25 Hz) Power failure: check for an inoperative power supply. Solid blue Local UID has been activated. Use this function to locate the server in a rack environment. Blinking blue (300 msec) Remote UID has been activated.

Use this function to locate the server from a remote location. LED Color State Status Activity LED Green Solid On SAS drive installed Green Blinking I/O activity Status LED Red Solid On Failed drive for SAS/SATA with RSTe support Red Blinking at 1 Hz Rebuild drive for SAS/SATA with RSTe support Red Blinking with two blinks and one stop at 1 Hz Hot spare for SAS/SATA with RSTe support Red On for fi ve seconds, then off Power on for SAS/SATA with RSTe support Red Blinking at 4 Hz Identify drive for SAS/SATA with RSTe support