SuperServer 2029P-C1R(T) User's Manual 3.4 Chassis Components Storage Drives The SC213 chassis supports sixteen 2.5" storage drives (HDDs or SSDs) in drive carriers to simplify their removal from the chassis. These carriers also help promote proper airflow. For VROC configurations, refer to the VROC appendix in this manual. Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www. supermicro.com/products/nfo/files/storage/SBB-HDDCompList.pdf. The server also supports PCIe M.2 storage that can be installed directly on the motherboard. See Section 3.3.
Drive Carrier Indicators Each drive carrier has two LED indicators: an activity indicator and a status indicator. In RAID configurations, the status indicator lights to indicate the status of the drive. In non-RAID configurations, the status indicator remains off. See the table below for details.
42 Drive Carrier LED Indicators Color Blinking Pattern Behavior for Device Activity LED Off No drive, or SATA drive installed Blue Solid On SAS drive installed Blue Blinking I/O activity Status LED Red Solid On Failure of drive with RSTe support Red Blinking at 1 Hz Rebuild drive with RSTe support Red Blinking with two blinks and one stop at 1 Hz Hot spare for drive with RSTe support Red On for five seconds, then off Power on for drive with RSTe support Red Blinking at 4 Hz Identify drive with RSTe support