Supermicro SuperServer 4048B-TR4FT — Supermicro SuperServer 4048B-TR4FT User's Manual PDF Download

SUPERSERVER 4048B-TR4FT USER'S MANUAL Inner Rails 1 4 1 2 1 4 1 3 Figure 2-3. Installing the Inner Rails Figure 2-4. Inner Rails Installed on the Chassis Installing The Inner Rails on the Chassis Installing the Inner Rails 1. Confirm that the left and right inner rails have been correctly identified. 2. Place the inner rail firmly against the side of the chassis, aligning the hooks on the side of the chassis with the holes in the inner rail. 3. Slide the inner rail forward toward the front of the chassis until the rail clicks into the locked position, which secures the inner rail to the chassis. 4. Secure the inner rail to the chassis with the screws provided. 5.

Repeat steps 1 through 4 above for the other inner rail. Warning: do not pick up the server by the front handles. They are designed to pull the system from a rack only. 2-6