Supermicro SuperServer 4048B-TR4FT — Supermicro SuperServer 4048B-TR4FT User's Manual PDF Download

SUPERSERVER 4048B-TR4FT USER'S MANUAL ! Power Failure When this LED flashes, it indicates a failure in the redundant power supply. 3-3 Drive Carrier LEDs The chassis includes externally accessable SATA drives. Each drive carrier displays two status LEDs on the front of the carrier. Green : When illuminated, this LED indicates drive activity. It blinks on and off when that particular drive is being accessed This function is controlled by the backplane. Red : When illuminated, this LED indicates a drive failure. You should be notified by your system management software. 3-4 Power Supply LEDs On the rear of the power supply module, an LED displays the status. Solid Green :

When illuminated, indicates that the power supply is on. Solid Amber : When illuminated, indicates the power supply is plugged in and turned off, or the system is off but in an abnormal state. Blinking Amber : When blinking, this system power supply temperature has reached 63°C. The system will automatically power-down when the power supply temperature reaches 70°C and restarts when the power supply temperature goes below 60°C. 3-4