Supermicro SuperServer 4048B-TR4FT — Supermicro SuperServer 4048B-TR4FT User's Manual PDF Download

SUPERSERVER 4048B-TR4FT USER'S MANUAL PW_ON Connector The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button (with a setting in the BIOS - See Chapter 5). To turn off the power when the system is in suspend mode, press the button for 4 seconds or longer. Refer to the table on the right for pin definitions. Reset Connector The reset connector is located on pins 3 and 4 of JF1 and attaches to the reset button on the computer chassis. See the table on the right for pin definitions.

Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions. Overheat (OH)/Fan Fail/PWR Fail/UID LED Connect an LED cable to the OH/Fan Fail/ FP UID connection on pins 7 and 8 of JF1 to provide advanced warnings of chassis overheating or fan failure. It also works as the front panel UID LED indicator. The red LED takes precedence over the blue LED by default. Refer to the table on the right for pin definitions.

5-18 Power Button Pin Definitions (JF1) Pin# Definition 1 Signal 2 Ground Reset Button Pin Definitions (JF1) Pin# Definition 3 Reset 4 Ground PWR Fail LED Pin Definitions (JF1) Pin# Definition 5 3.3V 6 PWR Supply Fail OH/Fan Fail/PWR Fail/UID LED Pin Definitions (JF1) Pin# Definition 7 Red+ (Blue LED Cathode) 8 Blue+ (OH/Fan Fail/PWR Fail/ UID LED) OH/Fan Fail Indicator Status State Definition Off Normal On Overheat Flash­ ing Fan Fail