S UPER S ERVER 5017C-URF User's Manual Power The main power button is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system. 3-3 Control Panel LEDs The control panel located on the front of the SC815TQ-R500B chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Universal Information LED When this LED blinks red quickly, it indicates a fan failure and when blinking red slowly a power failure.

The LED will be blue when used for UID (Unit Identifier). When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain flashing or on as long as the indicated condition exists. See the table below for descriptions of the LED states. Figure 3-1. Universal Information LED States Note:

deactivating the UID LED must be performed in the same way it was activated. (If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and not with the UID button.) 3-2 Universal Information LED States State Indication Fast Blinking Red (1x/sec) Fan Fail Solid Red CPU Overheat Slow Blinking Red (1x/4 sec) Power Fail Solid Blue Local UID Button Depressed Blinking Blue IPMI-Activated UID