Supermicro 5017C-URF — SuperServer 5017C-URF User's Manual

S UPER S ERVER 5017C-URF User's Manual HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. Attach a hard drive LED cable to display SATA/ IDE disk activity. Refer to the table on the right for pin definitions. NIC1 LED The NIC1 (Network Interface Control­ ler) LED connection is located on pins 11 and 12 of JF1. Attach the NIC1 LED cable to display network activity. Refer to the table on the right for pin definitions. NIC2 LED The NIC2 (Network Interface Control­ ler) LED connection is located on pins 9 and 10 of JF1. Attach the NIC2 LED cable to display network activity. Refer to the table on the right for pin definitions.

UID/Overheat/Fan Fail LED Connect an LED cable to the Front UID and OH/Fan Fail connections on pins 7 and 8 of JF1 to display UID (Unit ID) signals or to provide ad­ vanced warnings for chassis overheat/ fan failure. Refer to the table on the right for pin defi nitions. Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin defini­ tions.

5-14 HDD LED Pin Definitions (JF1) Pin# Definition 13 Vcc 14 HD Active NIC1 LED Pin Definitions (JF1) Pin# Definition 11 Vcc 12 Ground NIC2 LED Pin Definitions (JF1) Pin# Definition 9 Vcc 10 Ground Unit ID LED Status Unit ID LED / OH / FF Pin Definitions (JF1) State Definition Pin# Definition Off UID Off 7 OH/Fan Fail Solid On UID On 8 UID LED Blinking System Overheat / Fan Failure Power Fail LED Pin Definitions (JF1) Pin# Definition 5 Vcc 6 Ground