S UPER S ERVER 5018D-MF User's Manual NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on pins 9 and 10. Attach NIC LED cables to NIC1 LED and NIC2 LED to display network activities for LAN 1 and LAN2. Refer to the table on the right for pin definitions. Overheat (OH)/Fan Fail/Front UID LED Connect an LED cable to the Front UID and OH/Fan Fail connections on pins 7 and 8 of JF1 to display UID (Unit ID) sig nals or to provide advanced warnings for chassis overheat/fan failure. Refer to the table on the right for pin definitions.
Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions. Reset Button The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a the hardware Reset Button on the computer case. Refer to the table on the right for pin definitions. Serial Ports The COM1 port is located on the I/O backpanel. COM2 is a header located on the the motherboard. See the table on the right for pin definitions.
5-16 LAN1/LAN2 LED Pin Definitions (JF1) Pin# Definition 9/11 3.3V Stby 10/12 Signal OH/Fan Fail LED Pin Definitions (JF1) Pin# Definition 7 Vcc/Blue UID LED 8 OH/Fan Fail LED OH/Fan Fail Indicator Status State Definition Off Normal On Overheat Flashing Fan Fail PWR Fail LED Pin Definitions (JF1) Pin# Definition 5 3.3V 6 PWR Supply Fail Reset Button Pin Definitions (JF1) Pin# Definition 3 Reset 4 Ground Serial Port Pin Definitions (COM1/COM2) Pin # Definition Pin # Definition 1 CDC 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 NC