Chapter 6: Advanced Chassis Setup Checking the Air Flow in the Chassis Make sure there are no wires or other objects obstructing the airflow in and out of the server. Pull all excess cabling out of the airflow path or use shorter cables. Checking the Air Flow Do not operate the server without drives or drive carriers in the drive bays. Use only recommended server parts. The control panel LEDs inform you of the overall system status. See Chapter 3: System Interface for details on the LEDs and the control panel buttons. 6-8 System Fans Eight heavy-duty fans provide cooling for the chassis. These fans circulate air through the chassis as a means of lowering the chassis internal temperature.
The chassis includes counter-rotating fans. Each fan unit is actually made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airflow and works to dampen vibration levels. System Fan Failure Fan speed is controlled by system temperature through IPMI. If a fan fails, the remaining fans will ramp up to full speed and the system will continue to run. Replace any failed fan at your earliest convenience with the same type and model. The failed fan can be identified through the IPMI. 6-15