SuperServer 5019S-L User's Manual Chapter 3: Maintenance and Component Installation Installing Fans Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fans will ramp up to full speed. Replace any failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan). Rear Mounting Screws 1. With the server powered on, remove the chassis cover and inspect the fans to see which one has failed. 2. Power down the server and remove power from the system as described in section 3.1. 3. Remove the fan housing from the chassis by removing the two screws which attach the housing to the chassis.
These screws are located in the mounting thru holes on either side of the fan housing. (See figure 6-10). Set these screws aside for later use. Power Supply Mid-chassis Mounting Screws 4. Disconnect the fan wiring from the connectors and carefully lift the fan housing out of the chassis. Figure 3-16. Removing/Replacing a Power Supply 5. To remove the fans from the fan housing, gently push upwards on the fan from the underside of the fan housing. Gently ease the fan out of the top of the housing. Power Supply Failure 6. Slide the replacement fan upwards through the bottom of the fan housing.
With only one power supply unit in the chassis, power must be completely removed from the server before removing and replacing the power supply unit. Removing the Power Supply 7. Reconnect the fan wiring and replace the fan housing in the chassis using the mounting screws previously set aside. 8. Power up the system and check that the fan is working properly before replacing the If the power is on, removing power from the system as described in Section 3.1. chassis cover.Optional Fan 1. Disconnect all wiring from the power supply. The SC510-203B can support up to three system fans to provide optimal cooling for different motherboard designs.
You may purchase a third system fan if additional cooling is required. 2. Remove the four screws which hold the power supply in the chassis. The two rear mounting screws are located at the rear of the chassis. The two mid-chassis mounting screws are accessed from the underside and extend upwards through the chassis. Set the screws aside for later use. Power Supply The 5019S-L includes a single 200 watt power supply. This power supply has an auto- switching capability, which enables it to automatically sense and operate at a 100V - 240V input voltage. 3. Remove the power supply from the chassis.
Installing a Power Supply If the power supply unit fails, the system will shut down and you will need to replace the unit. Replacement units can be ordered directly from Supermicro. 1. Replace the failed power supply with another identical power supply module. 2. Align the mounting thru holes on the power supply with the mounting holes in the chassis and reattach the power supply to the chassis using the four screws which were previously set aside 3. Connect the chassis wiring to the power supply. 4. Reattach the AC power cord and power on the system. 34 33