Supermicro 5028A-TN4 — Supermicro SUPERSERVER 5028A-TN4 User's Manual (Revision 1.0a) PDF

SUPERSERVER 5028A-TN4 User's Manual Chassis SC721TQ-250B mini-tower Dimensions: height 9.45" (240.03mm), width 8.27" (210.06mm), depth 11" (279.4mm) System Cooling One 12-cm fan System Input Requirements AC Input: 100-240 VAC, 50-60 Hz Rated Input Current: 5 Amp Power Supply Part# PWS-251-1H, Flex ATX Multi-output, 80 Plus Bronze level Rated Output Power: 250 W Rated Output Voltages: +12V Max:18 Amp; Min:1 Amp @100V-240V -12V Max: 3 Amp; Min: 0 Amp +5V Max:14 Amp; Min:0.5 Amp +3.3V Max: 12 Amp Min: 0.3Amp 5VSB Max: 2.5 Amp Min: 0 Amp Operating Environment Operating Temperature: 5°C ~ 35°C (41°F ~ 95°F) Non-Operating Temperature: -40°C ~ 60°C (-40°F ~ 140°F) Operating Relative Humidity:

8% to 90% (non-condensing) Non-Operating Relative Humidity: 5% to 95% (non-condensing) Regulatory Compliance Electromagnetic Emissions: FCC Class B, EN 55022 Class B, EN 61000-3-2/-3- 3, CISPR 22 Class B Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.

See www.dtsc.ca.gov/hazardouswaste/perchlorate” B-2