Supermicro SUPERSERVER 5028TK-HTR/HTTR — 6-9 Adapter Card Replacement

Chapter 6: Advanced Chassis Setup 6-9 Adapter Card Replacement Each serverboard drawer comes equipped with an adapter card which plugs into the backplane. In the unlikely event that the adapter card needs to be replaced, installation requires only a Phillips head screwdriver. Figure 6-11. Adapter Card Installation Adapter Card Removing the Adapter Card (Figure 6-11) 1. Disconnect the wiring connecting the adapter card to the serverboard. 2. Remove the serverboard drawer from the chassis. 3. Remove the serverboard from the serverboard drawer by removing the screws securing it to the drawer. Set the screws aside for later use. 4.

Remove the five screws securing the adapter card to the drawer and set them aside for later use. 5. Remove the adapter card from the serverboard drawer. Installing the Adapter Card (Figure 6-11) 1. Place the adapter card in the serverboard drawer, aligning the holes in the adapter card with the holes in the serverboard drawer. 2. Secure the adapter card to the serverboard drawer, using the five screws which were previously set aside. 3. Reconnect the wiring from the serverboard to the adapter card. 4. Return the serverboard drawer to the closed position in the chassis. 6-13