Supermicro SUPERSERVER 5028TK-HTR/HTTR — Accessing the Drive Bays

Chapter 6: Advanced Chassis Setup 6-10 Drive Bay Installation/Removal Accessing the Drive Bays SATA Drives: You do not need to access the inside of the chassis or remove power to replace or swap SATA drives. Proceed to the next step for instructions. You must use standard 1" high, SATA drives in the system. Note: Refer to Supermicro's web site for setup guidelines: com/support/manuals/>. The SC827HQ+ chassis contains four individual serverboards in separate node drawers (Figure 6-13). Each serverboard node controls a set of three hard drives. Note that if a serverboard node drawer is pulled out of the chassis, the hard drives associated with that node will power down as well. Figure 6-13.

Hard Drives and their Corresponding Serverboard Nodes SB: B SB: A SB: C SB: D 1 A 1 B 1 C 1 D 6-15 Serverboard Drawer Locations in the Chassis Serverboard B Controls HDDs B1, B2 and B3 Serverboard D Controls HDDs D1, D2 and D3 Serverboard A Controls HDDs A1, A2 and A3 Serverboard C Controls HDDs C1, C2 and C3