Supermicro SuperServer 5037C-T — 5037C-T.indb

S UPER S ERVER 5037C-T User's Manual Weight Gross (Bare Bone): 24 lbs. (10.9 kg.) System Cooling One whisper-quiet 12-cm exhaust fan System Input Requirements AC Input Voltage: 100-240 VAC Rated Input Current: 7A (115V) to 3.5A (240V) Rated Input Frequency: 50/60 Hz Power Supply Rated Output Power: 500W (Part# PWS-502-PQ) Rated Output Voltages: +3.3V (15A), +5V (20A), +12V (17A), -12V (0.5A), +5Vsb (3A) Operating Environment Operating Temperature: 10є to 35є C (50є to 95є F) Non-operating Temperature: -40є to 70є C (-40є to 158є F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity:

5 to 95% (non-condensing) Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV Certifi ed (Germany), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate” B-2