Supermicro 5038MD-H8TRF — Supermicro SuperServer 5038MD-H8TRF User's Manual (Revision 1.0) PDF

SuperServer 5038MD-H8TRF User's Manual 1.4 Chassis Features Control Panel The chassis front features a control panel to monitor node function and power off and on the entire system. Figure 1-2. Chassis Control Panel 10 1 2 3 Chassis Control Panel Features Item Feature Description 1 Node Status Indicators Eight numbered LEDs that indicate the status of each node. (see table below) 2 Power Fail LED Illuminated when one of the power supplies fails while any node is powered on. It is off during normal operation. 3 Main Power button Used to apply or remove power from the power supply to the server system. Whether on or off, standby power to the system remains on.

Node Status Indicators LED Appearance Description Solid Green The node is powered on and operating normally Blinking Green The node is in the process of shutting down Solid Red The node is detecting an overheated condition 1Hz Blinking Red The node is detecting a fan failure .25Hz Blinking Red The node is detecting a power failure Solid Blue The node local UID is on 1Hz Blinking Blue The node remote UID is on No Illumination The node is powered-down