Chapter 2 Installation in a Rack Installing the Outer Rails onto the Rack Each end of the assembled outer rail includes a bracket with square pegs to fit into your rack holes. If you have an older rack with round holes, these brackets must be removed, and you must use screws to secure the rail to the rack. 1. Align the square pegs on the front end of the rail with the square holes on the front of the rack (C). Push the rail into the rack until the quick release bracket snaps into place, securing the rail to the rack. Keep the rail horizontal. 2. Adjust the rail to reach just past the full depth of your rack making sure that rear bracket is level with the front bracket. 3.

Align the square pegs on the rear end of the rail to the holes on the rack (D) and push the rail into the rack until the quick release bracket snaps into place, securing the rail to the rack. 4. Repeat the procedure for the other outer rail assembly. 1 D Bracket with Square Pegs 1 C Figure 2-5. Installing the Outer Rails to the Rack Note: Figure is for illustrative purposes only. Always install servers at the bottom of a rack first. Stability hazard . The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over. 23