S UPER S ERVER 6015B-8 User's Manual 2-6 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SCSI drives and backplane have been properly installed and all connections have been made. 1. Accessing the drive bays All drives are accessable from the front of the server. For servicing the DVD- ROM and fl oppy drives, you will need to remove the top chassis cover. The SCSI disk drives can be installed and removed from the front of the chassis without removing the top chassis cover. 2. DVD-ROM and fl oppy disk drives A slim DVD-ROM and fl oppy drive should be preinstalled in your server.
Refer to Chapter 6 if you need to reinstall a DVD-ROM and/or fl oppy disk drive to the system. 3. Check the SCSI disk drives Depending upon your system's confi guration, your system may have one or more drives already installed. If you need to install SCSI drives, please refer to Chapter 6. 4. Check the airfl ow Airfl ow is provided by four sets of 40-mm fans (each set of fans consists of two fans that are mounted back to back). The system component layout was care- fully designed to direct suffi cient cooling airfl ow to the components that generate the most heat. Note that all power and data cables have been routed in such a way that they do not block the airfl ow generated by the fans. 5.
Supplying power to the system The last thing you must do is to provide input power to the system. Plug the power cord from the power supply module into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS) source. 2-10