Chapter 5: Advanced Serverboard Setup Serial Ports The COM1 serial port is located on the IO backplane. COM2 is a header on the serverboard (see serverboard layout for location). See the table on the right for pin defi nitions. Note: Pin 10 is included on the header but not on the port. NC indicates no connection. Power Fail Header Connect a cable from your power sup- ply to the Power Fail header to provide you with warning of a power supply failure. The warning signal is passed through the PWR_LED pin to indicate a power failure. See the table on the right for pin defi nitions. Note: This feature is only available when using redundant Supermicro power supplies.

Fan Headers The X7DBR-8 has fi ve fan headers, designated Fan1 through Fan5. Fan speed is controlled via Thermal Man- agement with a BIOS setting. See the table on the right for pin defi nitions. Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of a chassis intrusion.

5-15 Serial Port Pin Defi nitions (COM1/COM2) Pin # Defi nition Pin # Defi nition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 NC Power Fail Header Pin Defi nitions (JPWF) Pin# Defi nition 1 P/S 1 Fail Signal 2 P/S 2 Fail Signal 3 P/S 3 Fail Signal 4 Alarm Reset Fan Header Pin Defi nitions (Fan1-5) Pin# Defi nition 1 Ground (Black) 2 +12V (Red) 3 Tachometer 4 PWM Control Chassis Intrusion Pin Defi nitions (JL1) Pin# Defi nition 1 Intrusion Input 2 Ground