S UPER S ERVER 6015B-8 User's Manual 3rd Power Supply Fail Detect Enable/Disable The system can notify you in the event of a power supply failure. This feature assumes that three power supply units are installed in the chassis with one act- ing as a backup. If you only have one or two power supply units installed, you should disable this (the default setting) with J3P to prevent false alarms. See the table on right for pin defi nitions. Note: J3P should be disabled on the 6015B-8, which has only a single pow- er supply. JLAN Enable/Disable Change the setting of jumper JPL1 or JPL2 to enable or disable the onboard Ethernet (RJ45) ports JLAN1 and JLAN2, respectively.
See the table on the right for jumper settings. The default setting is enabled Watch Dog Enable/Disable JWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application is “hung up”. Pins 1-2 will cause WD to reset the system if an application is hung up. Pins 2-3 will generate a non-maskable interrupt sig- nal for the application that is hung up. See the table on the right for jumper settings. Watch Dog must also be en- abled in BIOS. Note: When enabled, the user needs to write their own application software to disable the Watch Dog Timer.
5-20 3rd Power Supply Fail Detect Enable/Disable Jumper Settings (J3P) Jumper Setting Defi nition Open Disabled Closed Enabled JLAN Enable/Disable Jumper Settings (JPL1, JPL2) Jumper Setting Defi nition Pins 1-2 Enabled Pins 2-3 Disabled Watch Dog Jumper Settings (JWD) Jumper Setting Defi nition Pins 1-2 Reset Pins 2-3 NMI Open Disabled