SuperServer 6019P-MT/MTR User's Manual System Cooling Four 4-cm counter-rotating fans provide the cooling for the system. It is very important that the chassis top cover is installed for the cooling air to circulate properly through the chassis and cool the components. Installing Fans Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fans will ramp up to full speed. Replace any failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan). Replacing a System Fan 1. If necessary, open the chassis while the power is running to determine which fan requires changing.
(Never run the server for an extended period of time with the chassis open.) 2. Power down the system as described in Section 3.1. 3. Next, remove the top chassis cover as described in Section 3.2. 4. Remove the failed fan's cable from the connector on the motherboard. 5. Gently pull upward to remove the failed fan from the housing. 6. Place the new fan into the vacant space in the housing. Make sure that the arrows on the side of the fan (indicating air direction) point in the same direction as the arrows on the other fans. 7. Connect the fan wires to the same fan header as the fan just removed. 8.
Plug the power cord into the rear of the power supply, power up the system and check that the fan is working properly before replacing the chassis cover. Air Shroud The air shroud is used to concentrate airflow to maximize fan efficiency. The air shroud does not require screws to set up. Installing the Air Shroud 1. Lay the chassis on a flat, stable surface and remove the chassis cover. 2. If necessary, move any cables that interfere with the air shroud placement. 3. Place the air shroud in the chassis. The air shroud fits just behind the fans. Slide the air shroud into the grooves just behind the fan rack. 4. Reroute any cables that were moved and replace the chassis cover. 36