SuperServer 6019P-MT/MTR User's Manual Reset Button The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case to reset the system. Refer to the table below for pin definitions. Power Fail LED The Power Fail LED connection is located on pins 15 and 16 of JF1. Refer to the table below for pin definitions. Fan Fail and UID LED Connect an LED cable to pins 7 and 8 of the front control panel to use the Overheat/Fan Fail LED connections. The LED on pin 8 provides warnings of overheat or fan failure. Refer to the tables below for pin definitions.
NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on pins 9 and 10. Attach NIC LED cables to NIC1 and NIC2 LED indicators to display network activities. Refer to the table below for pin definitions.
44 Reset Button Pin Definitions (JF1) Pins Definition 3 Reset 4 Ground Power LED Pin Definitions (JF1) Pins Definition 5 +3.3V 6 Power Fail LED OH/Fan Fail Indicator Status State Definition Off Normal On Overheat Flashing Fan Fail OH/Fan Fail LED Pin Definitions (JF1) Pin# Definition 7 Blue LED 8 OH/Fan Fail LED LAN1/LAN2 LED Pin Definitions (JF1) Pins Definition 9/11 +3.3V Stby 10/12 NIC Activity LED