S UPER S ERVER 6026T-3RF User's Manual 2-6 Checking the Serverboard Setup After you install the 6026T-3RF in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. Accessing the inside of the System 1. First, grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). 2. Next, depress the two buttons on the top of the chassis to release the top cover. 3. You can then lift the top cover from the chassis to gain full access to the inside of the server. Checking the Components and Setup 1. You may have one or two processors already installed into the serverboard.
Each processor needs its own heat sink. See Chapter 5 for instructions on processor and heat sink installation. 2. Your 6026T-3RF server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5. 3. If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards. 4. Make sure all power and data cables are properly connected and not blocking the chassis airfl ow. Also make sure that no cables are positioned in front of the fans. See Chapter 5 for details on cable connections. 2-8